Specification

Specification                                                  Blood Glucose                                                                                Uric Acid

Strip model                                                         Y330                                                                                            YU330

Test range                         20 mg/dL to 600 mg/dL(1.1 mmol/L to 33.3 mmol/L)                       3.04 mg/dL to 19.96 mg/dL(181 µmol/L to 1188 µmol/L)

Target blood                                                 Fresh capillary whole blood                          Fresh capillary whole blood and venous whole blood

Accuracy                                                 <100mg/dL:Within ±15mg/dL                                          ≤ 5.04 mg/dL:Within±1.01mg/dL

                                                                 ≥100mg/dL:Within ±15%                                                  ≤ 5.04 mg/dL:Within ±20%

Sample volume                                                 1µL                                                                                      3 µL

Optional function                       Voice broadcast、Backlight、Bluetooth

Shelf life for strip                                                 Unopened:24 months                                                Unopened:18 months

                                                                            After opening:3 months                                              After opening:3 months

Measuring time                                                &nbsp;    <10 seconds                                                                   <10 seconds

Memory groups                                                 250 groups              &nbsp;                                                             250 groups

Atmospheric pressure range                           50 kPa to 106 kPa                                                 ;            50 kPa to 106 kPa

Storage Ambient temperature range for meter                             -10 °C~ +50 °C                                  &nbsp;      -10 °C~ +50 °C

Storage Ambient temperature range for strip                                  4°C-30°C             ;                                          4°C-30°C

Testing Ambient temperature range for strip.              &nbsp;                 10°C-40°C                                                      10°C-40°C

Hematocrit                                                                              &nbsp;        30%-60%                                                       30%-60%